Run 100 mini-gels with fewer prep steps and faster reads. Choose your NuView™ Tris-Glycine precast gels, drop in the Mini-PRO™ vertical cell, and use SingleShot™ TGS and TruSep™ 2× Sample Buffer for rapid, repeatable workflows. With NuView™ stain, visualize bands in ~2 minutes—no post-stain required.
What’s included
-
Precast Gels (100x)
Your choice of NuView™ Tris-Glycine mini gels (typical options: 8%, 10%, 12%, 4–20%; 10, 12, 15, or 17-well; 8×10 or 8.5 x 10cm cassette).
-
Electrophoresis Cell (1x)
Mini-PRO™ Vertical Electrophoresis Cell — compatible with NuSep NG 8×10 cm mini gels, NB 8.5×10 cm gels, or Bio-Rad TGX Protean gels.
-
Running Buffer (5x)
SingleShot™ TGS (5 × 10 L packets; makes 50 L total) — sufficient for ~100 mini-gel runs in most mini tanks.*
-
Protein Ladder (1x)
Pre-Stained Protein MW Marker (10–250 kDa) — suitable for ≥100 lanes at ~5 µL per lane.
-
Sample Loading Buffer (2x)
TruSep™ 2× Sample Loading Buffer — 2 × 10 mL (20 mL total). Comfortable coverage for ≥100 gels at typical 10–20 µL loads (10–15-well formats).†
-
Pipette Tips (200x)
Gel-loading Pipette Tips — 200 tips total for precise lane loading.
*Typical mini-cell buffer volume is ~400–500 mL per run; actual usage varies by tank and protocol.
†Rule of thumb for 2× buffer: buffer volume per lane = (load volume ÷ 2). For 100 gels at 10–20 µL loads and common well counts, 20 mL 2× comfortably exceeds requirements.
Why this kit
-
Faster results — NuView™ gels let you check bands in ~2 min.
-
Less prep — SingleShot™ TGS and TruSep™ 2× reduce measuring, mixing, and pH variability.
-
Consistent performance — precast gels + pre-measured buffers = repeatable transfers and clean band shapes.
-
Ready on day 1 — everything you need to run 100 gels, in one box.
What you pick at checkout
-
Gel model: select %T / gradient and cassette format to match your targets.
-
Cell tank option: Mini-PRO™ vertical cell (compatible with NuSep NG/NB and TGX Protean formats).
Good to know
- Store gels at 2–8 °C; avoid freezing. Keep buffers tightly capped; mix 2× sample buffer 1:1 with sample.
- For best results, equilibrate gels to room temperature before loading; avoid overfilling wells.
- Compatible with common mini-cell accessories and standard power supplies.
Recommended add-ons
- Extra protein marker and pipette tips for heavy-throughput labs.
- Transfer supplies (NC or PVDF membranes, blotting paper) if you plan Western blots after SDS-PAGE.
Questions or want to mix multiple gel models? Let us know here.